﻿<?xml version="1.0" encoding="UTF-8"?>
<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns="http://purl.org/rss/1.0/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:sy="http://purl.org/rss/1.0/modules/syndication/" xmlns:sciepub="http://www.sciepub.com" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" xmlns:prism="http://prismstandard.org/namespaces/basic/1.2/">
  <channel rdf:about="http://www.sciepub.com/portal/Journals">
    <title>American Journal of Mechanical Engineering</title>
    <link>http://www.sciepub.com/journal/AJME</link>
    <description>American Journal of Mechanical Engineering is a peer-reviewed, open access journal that publishes original research articles and review articles in all areas of Mechanical Engineering. The aim of the journal is to provide academicians, researchers and professionals a platform to share cutting-edge development in the field of Mechanical Engineering.</description>
    <dc:publisher>Science and Education Publishing</dc:publisher>
		<dc:language>en</dc:language>
		<dc:rights>2013 Science and Education Publishing Co. Ltd All rights reserved.</dc:rights>
		<prism:publicationName>American Journal of Mechanical Engineering</prism:publicationName>
		14
		1
		January 2026
		<prism:copyright>2013 Science and Education Publishing Co. Ltd All rights reserved.</prism:copyright>
    <items>
      <rdf:Seq>
        <rdf:li resource="http://pubs.sciepub.com/ajme/14/1/1"/>
<rdf:li resource="http://pubs.sciepub.com/ajme/14/1/2"/>
      </rdf:Seq>
    </items>
  </channel>
  <item rdf:about="http://pubs.sciepub.com/ajme/14/1/1">
<title>
Mechanical Performance and Crack Propagation Resistance in 3D-Printed Nylon-Carbon Composites
</title>
<link>http://pubs.sciepub.com/ajme/14/1/1</link>
<description>
<![CDATA[<b>  </b>This study investigates the fracture toughness of 3D-printed Polyamide 12 (PA-12) reinforced with carbon fiber. Tensile tests demonstrated an average ultimate tensile strength of 74.24 MPa. Compact tension tests on specimens (W=14 mm, B=4 mm, a=8 mm) revealed a critical load of 1.8 kN. The fracture toughness (K<SUB>IC</SUB>) was calculated as 36.8 MPa√m following ASTM E399 standards. Using an experimental elastic modulus of 5 GPa typical for carbon fiber reinforced PA-12 composites, the corresponding critical strain energy release rate (G<SUB>IC</SUB>) was determined to be <b>245</b> kJ/m². This substantial fracture resistance, combined with the observed mixed-mode failure mechanisms including fiber bridging and matrix deformation, indicates that 3D-printed PA-12 carbon fiber composites offer promising damage tolerance for structural applications.]]>
</description>
<dc:creator>
Saeed  Al-Noman, Somia  Alfatih M. S., Mohammed  Ghazi Gronfula, Galal  Al-Mekhlafi, Mohammed  Y. Abdellah, Abdulmajid  AlAliw, Mohammed  K. Hassan
</dc:creator>
<dc:date>2026-01-08</dc:date>
<dc:publisher>Science and Education Publishing</dc:publisher>
<prism:publicationDate>2026-01-08</prism:publicationDate>
<prism:number>1</prism:number>
<prism:volume>14</prism:volume>
<prism:startingPage>1</prism:startingPage>
<prism:endingPage>6</prism:endingPage>
<prism:doi>10.12691/ajme-14-1-1</prism:doi>
</item>
<item rdf:about="http://pubs.sciepub.com/ajme/14/1/2">
<title>
Design and Field Testing of a Battery-Assisted, Mechanically Buffered Floating Water Pumping Prototype for Smallholder Irrigation in Benin
</title>
<link>http://pubs.sciepub.com/ajme/14/1/2</link>
<description>
<![CDATA[This study presents the design and preliminary field testing of a battery-assisted, mechanically buffered floating water pumping prototype developed for smallholder irrigation in contexts with limited access to energy and infrastructure. The system is conceived as a proof of concept that combines mechanical energy buffering, via compression springs and a flywheel, with intermittent electromagnetic assistance supplied by a battery, rather than as a fully autonomous energy system. The prototype was designed, assembled, and tested under real field conditions in the commune of N’Dali, northern Benin. At this exploratory stage, the evaluation focused exclusively on functional behavior and hydraulic performance, while energetic efficiency was intentionally excluded from the scope of the analysis. Field experiments based on volumetric measurements yielded a mean discharge of 0.21 L s-1 under a total dynamic head of approximately 0.87 m. The prototype exhibited stable flotation, reliable mechanical operation, and required minimal human intervention during test cycles. Although energy consumption, efficiency, and long-term durability were not quantified, the results demonstrate the technical feasibility of a low-energy, mechanically assisted floating pumping system adapted to smallholder irrigation. The prototype therefore constitutes a robust experimental platform for subsequent instrumentation, energy performance assessment, and design optimization.]]>
</description>
<dc:creator>
Chaim  Vivien DOTO, Sylvain  SOROTORI, Djigbo  Félicien BADOU, Samuel  Fernand GOUDA, Hyppolite  AGADJIHOUEDE
</dc:creator>
<dc:date>2026-02-05</dc:date>
<dc:publisher>Science and Education Publishing</dc:publisher>
<prism:publicationDate>2026-02-05</prism:publicationDate>
<prism:number>1</prism:number>
<prism:volume>14</prism:volume>
<prism:startingPage>7</prism:startingPage>
<prism:endingPage>13</prism:endingPage>
<prism:doi>10.12691/ajme-14-1-2</prism:doi>
</item>
</rdf:RDF>